Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS)

Description of method

LA-ICP-MS is a sensitive analytical method for rapid multi-element determination in the trace and ultratrace range of geological, ceramic and radioactive solid sample materials and technical products. The sample material to be investigated is vaporized in a laser plasma by focussed laser radiation and transported with argon into the inductively coupled plasma ion source of an ICP-MS. The positively charged ions are extracted from the inductively coupled plasma through an interface into the high vacuum of the mass spectrometer and separated in the mass-spectrometric separation system according to their mass/charge ratio and energy/charge ratio and detected by a secondary electron multiplier. By means of double-focussing sector-field ICP-MS it is possible to separate isobaric interferences of disturbing molecular and atomic ions of the analyte (e.g. 56Fe+ and 40Ar16O+), the application of the collision cell in ICP-MS permits the dissociation of disturbing molecular ions.

Features of LA-ICP-MS

  • simultaneous concentration determination of all chemical elements (except noble gases) in the concentration range from 100 % to sub-ng g-1;
  • direct bulk, trace and ultratrace analysis of metals, alloys, semiconductors and preferentially ceramics and insulators (detection limits: » 1 ng g-1) without sample preparation;
  • isotope analysis of samples of natural isotopic composition and enriched stable tracers;
  • isotope dilution analysis using stable tracers for improving the accuracy and reproducibility of the analytical results;
  • elemental analysis of thick films (>1µm); microrange analysis;
  • The quantification is performed via reference materials of similar matrix composition using relative element sensitivity factors, reproducibility of the results: 10 - 20 %; if no suitable standard samples are available, the analytical results are indicated with an error factor of 2-3;
  • suitable samples are compact solids; powder samples are pressed into targets (10 mm x 10 mm x 3 mm).

Analysis examples

  • tissue samples (e.g. brain samples) BrainMet
  • direct trace and ultratrace analysis of metals, semiconductors and ceramics (e.g. SiC, WC, BC4, BN, ZrO2, Al2O3, HTSL) , ultratrace analysis of long-lived radionuclides in radioactive waste (e.g. concrete), superpure graphite, superpure metals (Cu, Pt, Pd, Ag, Au).

Contact

Herr Dr. V. Nischwitz Tel.: 02461-61 1673 


Servicemeu

Homepage

Logo

 

 

 

YOUR OPINION MATTERS!

 

Dear visitor,

To make our website suit your needs even more and to give it a more appealing design, we would like you to answer a few short questions.

Answering these questions will take approx. 10 min.

Start now Close window

Thank you for your support!

 

In case you have already taken part in our survey or in case you have no time to take part now, you can simply close the window by clicking "close".

If you have any questions on the survey, please do not hesitate to contact: webumfrage@fz-juelich.de.

 

Your Team at Forschungszentrum Jülich

 

Note: Forschungszentrum Jülich works with the market research institute SKOPOS to anonymously conduct and analyze the survey. SKOPOS complies with the statutory requirements on data protection as well as with the regulations of ADM (Arbeitskreis Deutscher Markt- und Sozialforschungsinstitute e.V.) and ESOMAR (Europäische Gesellschaft für Meinungs- und Marketingforschung). Your data will not be forwarded to third parties.